Format

Send to

Choose Destination
See comment in PubMed Commons below
Catheter Cardiovasc Interv. 2013 Aug 1;82(2):266-73. doi: 10.1002/ccd.24481. Epub 2013 Mar 25.

Nine-month results of the REFORM study: a prospective, single-arm, multicenter clinical study of the safety and effectiveness of the Formula™ balloon-expandable stent for treatment of renal artery stenosis.

Author information

1
Department of Cardiology, Swedish Medical Center, Seattle, Washington, USA. robert.bersin@swedish.org

Abstract

OBJECTIVES:

To evaluate the 9-month safety and effectiveness outcomes of the Formula™ balloon-expandable renal stent (Cook Medical, Bloomington, IN) for the treatment of atherosclerotic renal artery stenosis (RAS) following suboptimal angioplasty.

BACKGROUND:

Atherosclerotic RAS can cause hypertension and ischemic nephropathy. When clinically indicated, an interventional approach with renal angioplasty and stent implantation is the preferred method for revascularization of atherosclerotic renal artery stenoses.

METHODS:

The REFORM study is a prospective, multicenter, single-arm study of stent implantation following suboptimal PTRA using the Formula stent. One hundred patients with atherosclerotic ostial renal artery lesions =18 mm in length with a >50% residual stenosis following PTA were enrolled. The primary endpoint was 9-month primary patency.

RESULTS:

The 9-month primary patency rate was 91.7%. The 9-month major adverse event rate was 2.2%. Mean systolic blood pressure was significantly decreased at follow-up (from 150 ± 21 mm Hg at baseline to 141 ± 21 mm Hg at 9 months; P = 0.003). Mean serum creatinine (SCr) level and mean estimated glomerular filtration rate (eGFR) were not significantly different at 9 months. A clinically meaningful improvement in renal function (i.e., =25% increase in eGFR or =0.5 mg/dl decrease in SCr) was observed in 9% of patients at 1 month and 12% of patients at 9 months. A clinically meaningful decline in renal function (i.e., =25% decrease in eGFR or =0.5 mg/dl increase in SCr) was observed in only 3% of patients at 1 month and 7% of patients at 9 months.

CONCLUSIONS:

The Formula stent was safe and effective in treating atherosclerotic RAS following suboptimal angioplasty.

TRIAL REGISTRATION:

ClinicalTrials.gov NCT00631540.

KEYWORDS:

hypertension; ischemic nephropathy; renal artery disease; renal failure; renal stent; revascularization

Comment in

PMID:
22581488
DOI:
10.1002/ccd.24481
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Wiley
    Loading ...
    Support Center