Format

Send to

Choose Destination
Clin Oral Investig. 2013 Jan;17(1):243-9. doi: 10.1007/s00784-012-0701-9. Epub 2012 Mar 14.

Clinical evaluation of the performance and safety of a new dentine substitute, Biodentine, in the restoration of posterior teeth - a prospective study.

Author information

1
Service d'Odontologie Gaston Berger, CHU de Marseille, 17-19 boulevard Mireille Lauze, 13010, Marseille, France.

Abstract

OBJECTIVES:

A multicentric randomized, 3-year prospective study was conducted to determine for how long Biodentine, a new biocompatible dentine substitute, can remain as a posterior restoration.

MATERIALS AND METHODS:

First, Biodentine was compared to the composite Z100®, to evaluate whether and for how long it could be used as a posterior restoration according to selected United States Public Health Service (USPHS)' criteria (mean ± SD). Second, when abrasion occurred, Biodentine was evaluated as a dentine substitute combined with Z100®.

RESULTS:

A total of 397 cases were included. This interim analysis was conducted on 212 cases that were seen for the 1-year recall. On the day of restoration placement, both materials obtained good scores for material handling, anatomic form (0.12 ± 0.33), marginal adaptation (0.01 ± 0.10) and interproximal contact (0.11 ± 0.39). During the follow-up, both materials scored well in surface roughness (≤1) without secondary decay and post-operative pain. Biodentine kept acceptable surface properties regarding anatomic form score (≤1), marginal adaptation score (≤2) and interproximal contact score (≤1) for up to 6 months after placement. Resistance to marginal discoloration was superior with Biodentine compared to Z100®. When Biodentine was retained as a dentine substitute after pulp vitality control, it was covered systematically with the composite Z100®. This procedure yielded restorations that were clinically sound and symptom free.

CONCLUSIONS:

Biodentine is able to restore posterior teeth for up to 6 months. When subsequently covered with Z100®, it is a convenient, efficient and well tolerated dentine substitute.

CLINICAL RELEVANCE:

Biodentine as a dentine substitute can be used under a composite for posterior restorations.

PMID:
22411260
PMCID:
PMC3536989
DOI:
10.1007/s00784-012-0701-9
[Indexed for MEDLINE]
Free PMC Article