Format

Send to

Choose Destination
See comment in PubMed Commons below
Eur J Nucl Med Mol Imaging. 2012 May;39(5):852-63. doi: 10.1007/s00259-012-2077-0. Epub 2012 Mar 6.

Whole-body FDG PET/CT is more accurate than conventional imaging for staging primary breast cancer patients.

Author information

1
Medical Faculty, Department of Diagnostic and Interventional Radiology, Univ Dusseldorf, 40225 Dusseldorf, Germany.

Abstract

PURPOSE:

This retrospective study aimed (1) to compare the diagnostic accuracy of whole-body FDG PET/CT for initial breast cancer staging with the accuracy of a conventional, multimodal imaging algorithm, and (2) to assess potential alteration in patient management based on the FDG PET/CT findings.

METHODS:

Patients with primary breast cancer (106 women, mean age 57 ± 13 years) underwent whole-body FDG PET/CT and conventional imaging (X-ray mammography, MR mammography, chest plain radiography, bone scintigraphy and breast, axillary and liver ultrasonography). The diagnostic accuracies of FDG PET/CT and a conventional algorithm were compared. Diagnostic accuracy was assessed in terms of primary tumour detection rate, correct assessment of primary lesion focality, T stage and the detection rates for lymph node and distant metastases. Histopathology, imaging or clinical follow-up served as the standards of reference.

RESULTS:

FDG PET/CT was significantly more accurate for detecting axillary lymph node and distant metastases (p = 0.0125 and p < 0.005, respectively). No significant differences were detected for other parameters. Synchronous tumours or locoregional extraaxillary lymph node or distant metastases were detected in 14 patients (13%) solely by FDG PET/CT. Management of 15 patients (14%) was altered based on the FDG PET/CT findings, including 3 patients with axillary lymph node metastases, 5 patients with extraaxillary lymph node metastases, 4 patients with distant metastases and 3 patients with synchronous malignancies.

CONCLUSION:

Full-dose, intravenous contrast-enhanced FDG PET/CT was more accurate than conventional imaging for initial breast cancer staging due to the higher detection rate of metastases and synchronous tumours, although the study had several limitations including a retrospective design, a possible selection bias and a relevant false-positive rate for the detection of axillary lymph node metastases. FDG PET/CT resulted in a change of treatment in a substantial proportion of patients.

PMID:
22392069
DOI:
10.1007/s00259-012-2077-0
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Springer
    Loading ...
    Support Center