Format

Send to

Choose Destination
See comment in PubMed Commons below
J Arthroplasty. 2012 Jun;27(6):1069-74. doi: 10.1016/j.arth.2011.09.012. Epub 2011 Nov 15.

Imaging periprosthetic osteolysis around total knee arthroplasties using a human cadaver model.

Author information

  • 1Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.

Abstract

We examined the sensitivity and accuracy of measuring osteolysis around total knee arthroplasty (TKA) on radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) in a cadaver model. Fifty-four simulated osteolytic defects ranging from 0.7 to 14 cm(3) were created in 6 cadaver knees implanted with either a cemented or an uncemented TKA. Three blinded investigators assessed the presence, location, and volume of defects on radiographs and CT and MRI scans with metal reduction protocols. Both CT and MRI had significantly higher sensitivities and specificities than did plain radiographs (P < .005). Overall, there was no difference in the accuracy of defect volume measurements between CT and MRI (P = .574). This study demonstrates the limitations of radiographs and the high sensitivity and specificity of both CT and MRI in assessing osteolysis around TKA.

PMID:
22085797
DOI:
10.1016/j.arth.2011.09.012
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Support Center