Format

Send to

Choose Destination
Diabetes Res Clin Pract. 2011 Dec;94(3):e78-82. doi: 10.1016/j.diabres.2011.08.025. Epub 2011 Sep 25.

Reproducibility of multiple repeated oral glucose tolerance tests.

Author information

1
Discipline of Exercise Sciences, School of Medical Sciences, RMIT University, Melbourne, Australia. brett.gordon@rmit.edu.au

Abstract

We assessed the oral glucose tolerance test's (OGTT) ability to produce consistent results for estimating insulin sensitivity over four consecutive days. Individual coefficients of variation for OGIS and Stumvoll-ISI were 7.8% and 14.4% with no statistically significant difference between days. Thereby, indicating repeated OGTT's are reliable for estimating insulin sensitivity.

PMID:
21945562
DOI:
10.1016/j.diabres.2011.08.025