Format

Send to

Choose Destination
See comment in PubMed Commons below
J Thorac Cardiovasc Surg. 2012 Jun;143(6):1370-6. doi: 10.1016/j.jtcvs.2011.07.014. Epub 2011 Aug 11.

Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

Author information

1
Department of Surgery/Division of Cardiovascular Surgery, Mayo Clinic College of Medicine, Rochester, MN 55905, USA.

Abstract

OBJECTIVE:

The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device.

METHODS:

From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared.

RESULTS:

Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P < .001), worse right ventricular dysfunction (right ventricular end-diastolic area, 33.6 ± 6.2 mm vs 31.6 ± 8.5 mm; P = .05), higher mean right atrial pressure (17.4 ± 7.1 mm Hg vs 14.9 ± 5.1 mm Hg; P = .03), and a higher Kormos score (2.6 ± 2.1 vs 1.2 ± 1.4; P = .0008) preoperatively. One month after surgery, tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups.

CONCLUSIONS:

In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle.

PMID:
21839483
DOI:
10.1016/j.jtcvs.2011.07.014
[Indexed for MEDLINE]
Free full text
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Support Center