Acute outflow obstruction of hepatic veins in rabbits: quantitative analysis of hepatic perfusion with contrast-enhanced sonography

J Ultrasound Med. 2011 May;30(5):635-42. doi: 10.7863/jum.2011.30.5.635.

Abstract

Objectives: To compare time-enhancement curve parameters of contrast-enhanced sonography in acute partial hepatic venous outflow obstruction with those of a baseline study.

Methods: Contrast-enhanced sonography was performed in 11 rabbits with bolus administration of a sulfur hexafluoride contrast agent (0.1 mL/kg). After baseline scanning for 3 minutes, a 5.3F balloon catheter was placed into the left hepatic vein. Obstruction was artificially induced by 0.4-mL balloon inflation, and sonography was repeatedly performed thereafter. On images stored with 1-second intervals, 2 × 2-mm regions of interest were placed, and mean luminosity was measured. Time-enhancement curves were plotted, and contrast arrival times, peak enhancement values, peak enhancement times, 50% wash-out times, and 3-minute wash-out rates were obtained. Paired t tests were performed to evaluate the significance of differences in the parameters between baseline and obstruction.

Results: On baseline sonography, the median contrast arrival time, peak enhancement value, peak enhancement time, 50% wash-out time, and 3-minute wash-out rate were 6 (range, 4-8; mean ± SD, 5.9 ± 1.2) seconds, 188.5 (104.7-209.5; 178.4 ± 33.1) arbitrary units, 19 (14-27; 19.8 ± 4.1) seconds, 75 (60-101; 78.2 ± 13.9) seconds, and 89.7% (81.3%-95.1%; 88.4% ± 4.9%), respectively. With obstruction, those values were 7 (5-12; 6.9 ± 2.3) seconds, 202.8 (98.2-215.1; 186.0 ± 39.3) arbitrary units, 31 (17-59; 32 ± 11.6) seconds, 101 (47-136; 96.2 ± 23.6) seconds, and 79.2% (66.2%-88.8%; 79.1% ± 7.6%). Compared with baseline, the peak enhancement time was significantly delayed from 19 to 31 seconds (P = .0027), 50% wash-out time significantly delayed from 75 to 101 seconds (P = .0209), and 3-minute wash-out rate significantly decreased from 89.7% to 79.2% (P < .0001) with obstruction, but there were no significant differences in contrast arrival times and peak enhancement values (P = .0756 and .2179).

Conclusions: Contrast-enhanced sonography can provide quantitative assessment of microbubble congestion in partial hepatic venous outflow obstruction. The peak enhancement time and 50% wash-out time are delayed and 3-minute wash-out rate is decreased in rabbits with artificially induced obstruction compared with a baseline study.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Blood Flow Velocity
  • Contrast Media
  • Hepatic Veins / diagnostic imaging*
  • Hepatic Veins / physiopathology*
  • Hepatic Veno-Occlusive Disease / diagnostic imaging*
  • Hepatic Veno-Occlusive Disease / physiopathology*
  • Liver Circulation*
  • Male
  • Perfusion Imaging / methods*
  • Phospholipids
  • Rabbits
  • Sulfur Hexafluoride
  • Ultrasonography / methods*

Substances

  • Contrast Media
  • Phospholipids
  • contrast agent BR1
  • Sulfur Hexafluoride