J Rehabil Res Dev. 2011;48(2):115-24.

Telerehabilitation assessment using the Functioning Everyday with a Wheelchair-Capacity instrument.

Author information

1
University of Pittsburgh, Department of Rehabilitation Sciences and Technology, 6425 Penn Avenue, Suite 401, Pittsburgh, PA 15206, USA. rms35@pitt.edu

Abstract

This study explored the interrater reliability between a generalist practitioner administering the Functioning Everyday with a Wheelchair-Capacity (FEW-C) in person (IP) and a remote expert practitioner observing via telerehabilitation (TR) from more than 100 miles away. Each of the 46 participants was simultaneously rated by both the IP and TR practitioner, who were masked to each other's results. The IP-TR raters demonstrated excellent interrater reliability, with an intraclass correlation coefficient of 0.91 for the total FEW-C and 0.96, 0.88, and 0.90 for the constructs of independence, safety, and quality, respectively. Internal consistency (Cronbach alpha) was 0.94 for the total FEW-C tool and 0.91, 0.83, and 0.82 for independence, safety, and quality, respectively, indicating good internal consistency without redundancy. Using TR and the FEW-C, an expert practitioner more than 100 miles away was able to accurately assess the functional mobility needs of clients being assessed for new wheeled mobility devices.