Infect Control Hosp Epidemiol. 2011 Mar;32(3):286-8. doi: 10.1086/658329.

Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on hospital operations and microbial reduction.

Author information

1
Xenex Healthcare Services, Austin, Texas 78746, USA. mark.stibich@xenex.com

Abstract

This study evaluated the use of pulsed-xenon ultraviolet (PX-UV) room disinfection by sampling frequently touched surfaces in vancomycin-resistant enterococci (VRE) isolation rooms. The PX-UV system showed a statistically significant reduction in microbial load and eliminated VRE on sampled surfaces when using a 12-minute multiposition treatment cycle.