Intensive Care Med. 2011 Apr;37(4):678-85. doi: 10.1007/s00134-010-2116-x. Epub 2011 Jan 27.

Intervention to reduce catheter-related bloodstream infections in a pediatric intensive care unit.

Author information

1
Paediatric Intensive Care Unit, Department of Paediatrics, Hospital Universitario Central de Asturias, University of Oviedo, Oviedo, Asturias, Spain. corsino.rey@sespa.princast.es

Abstract

OBJECTIVE:

Identification of catheter-related bloodstream infection (CR-BSI) risk factors and determination of whether intervention related to identified risk factors would reduce CR-BSI rates.

DESIGN:

Prospective, observational, interventional and interrupted time-series study.

SETTING:

Pediatric Intensive Care Unit (PICU) in a university hospital.

METHODS:

During a 7-year period, 609 central venous catheters (CVC) were placed in 389 patients. CR-BSI risk factors were determined by multivariate analysis during two periods (January 2000-November 2002 and January 2003-April 2007). An intervention to reduce identified risk factors was performed after the first period. CR-BSI rates per 1,000 catheters-days were compared during the two periods.

RESULTS:

The CR-BSI rate was 11.94 [(95% CI 7.94-15.94)/1,000 catheter-days during the first period]. Weight [OR 0.96 (0.91-0.99)], parenteral nutrition (PN) [OR 3.38 (1.40-8.19)] and indwelling time (IT) [OR 1.08 (1.02-1.14)] were CR-BSI risk factors. Practice changes aimed at reducing PN and IT were introduced. PN decreased from 49.8% [95% CI (49.7-49.9)] to 26.7% [(95% CI 26.6-26.8)] (p < 0.001), and IT dropped from 9.92 (95% CI 9.09-10.75) to 8.13 (95% CI 7.47-8.79) days (p < 0.001). The CR-BSI rate was reduced to 3.05 (95% CI 0.93-5.17)/1,000 catheter-days. During the last period, PN and IT were no longer CR-BSI risk factors. Type of catheterisation (guide wire exchange) [OR 6.66 (1.40-31.7)] was the only CR-BSI risk factor.

CONCLUSIONS:

PN and IT were independent CR-BSI risk factors during the first period. An intervention focused on PN and IT reduction resulted in a sustained decrease of CR-BSI rates in our PICU.