Format

Send to

Choose Destination
See comment in PubMed Commons below
Europace. 2011 Feb;13(2):193-204. doi: 10.1093/europace/euq384. Epub 2010 Oct 30.

Efficacy of adjunctive ablation of complex fractionated atrial electrograms and pulmonary vein isolation for the treatment of atrial fibrillation: a meta-analysis of randomized controlled trials.

Author information

1
Duke University Medical Center, Clinical Cardiac Electrophysiology Section of the Division of Cardiovascular Diseases, DUMC Box 31294, Durham, NC 27710, USA. kong0017@mc.duke.edu

Erratum in

  • Europace. 2011 Aug;13(8):1062.

Abstract

AIMS:

Although useful, percutaneous left atrial ablation for pulmonary vein isolation (PVI) does not eliminate atrial fibrillation (AF) in all patients. The ablation of complex fractionated atrial electrograms (CFAEs) has been proposed as an adjunctive strategy to improve the maintenance of sinus rhythm after PVI. Our objective was to analyse the efficacy of adjunctive CFAE ablation.

METHODS AND RESULTS:

We meta-analysed six randomized controlled trials (total, n=538) using random-effects modelling to compare PVI (n=291) with PVI plus CFAE ablation (PVI+CFAE) (n=237). The primary outcome was freedom from AF or other atrial tachyarrhythmias (ATs) after a single ablation with or without antiarrhythmic drugs. Following a single ablation, PVI+CFAE improved the odds of freedom from any AF/AT compared with PVI alone (odds ratio 2.0, 95% confidence interval 1.04-3.8, P=0.04) at ≥3-month follow-up. There was moderate heterogeneity among trials (I2=63.0%). Complex fractionated atrial electrogram ablation significantly increased mean procedural (178.5±66.9 vs. 331.5±92.6 min, P<0.001), mean fluoroscopy (59.5±22.2 vs. 115.5±35.3 min, P<0.001), and mean radiofrequency (RF) energy application times (46.9±36.6 vs. 74.4±43.0 min, P<0.001).

CONCLUSIONS:

Pulmonary vein isolation followed by adjunctive CFAE ablation is associated with increased freedom from AF after a single procedure. Adjunctive CFAE ablation increased procedural, fluoroscopy, and RF application times, and the risk/benefit profile of adjunctive CFAE ablation deserves further evaluation with additional studies and longer-term follow-up.

PMID:
21037322
PMCID:
PMC3024038
DOI:
10.1093/europace/euq384
[Indexed for MEDLINE]
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Silverchair Information Systems Icon for PubMed Central Icon for PubMed Health
    Loading ...
    Support Center