Format

Send to

Choose Destination
See comment in PubMed Commons below
Appl Opt. 1991 Jun 20;30(18):2609-16. doi: 10.1364/AO.30.002609.

Optimal heterodyne detector array size for 1-microm coherent lidar propagation through atmospheric turbulence.

Abstract

The heterodyne detection efficiency for a 1-microm coherent atmospheric backscatter lidar was numerically calculated using a Monte Carlo technique which included a simple model for the effects of atmospheric turbulence. The results show that the heterodyne detection efficiency of a single-element detector is severely reduced by the effects of atmospheric turbulence, but that the use of an appropriate sized, multiple-element heterodyne detector array can overcome these effects. In addition, the statistical fluctuation (signal-to-noise ratio) of the lidar signal was also calculated and showed that the use of a heterodyne detector array can increase the accuracy to that for direct detection.

PMID:
20700250
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Loading ...