Value of retrospective fusion of PET and MR images in detection of hepatic metastases: comparison with 18F-FDG PET/CT and Gd-EOB-DTPA-enhanced MRI

J Nucl Med. 2010 May;51(5):692-9. doi: 10.2967/jnumed.109.068510. Epub 2010 Apr 15.

Abstract

The purpose of this study was to compare the accuracy of lesion detection and diagnostic confidence between (18)F-FDG PET/CT, gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI, and retrospectively fused PET and MRI (PET/MRI).

Methods: Thirty-seven patients (mean age +/- SD, 60.2 +/- 12 y) with suspected liver metastases underwent PET/CT and Gd-EOB-DTPA-enhanced MRI within 0-30 d (mean, 11.9 +/- 9 d). PET and Gd-EOB-DTPA-enhanced MR image data were retrospectively fused. Images were reviewed independently by 2 readers who identified and characterized liver lesions using PET/CT, Gd-EOB-DTPA-enhanced MRI, and PET/MRI. Each liver lesion was graded on a 5-point confidence scale ranging from definitely benign (grade of 1) to definitely malignant (grade of 5). The accuracy of each technique was determined by receiver-operating-characteristic analysis. Histopathology served as the standard of reference for all patients with malignant lesions.

Results: A total of 85 liver lesions (55 liver metastases [65%] and 30 benign lesions [35%]) were present in 29 (78%) of the 37 patients. Twenty-four (65%) of the 37 patients had liver metastases. The detection rate of liver lesions was significantly lower for PET/CT than for Gd-EOB-DTPA-enhanced MRI (64% and 85%; P = 0.002). Sensitivity in the detection and characterization of liver metastases for PET/CT, Gd-EOB-DTPA-enhanced MRI, PET/MRI in reader 1, and PET/MRI in reader 2 was 76%, 91%, 93%, and 93%, respectively; the respective specificity values were 90%, 100%, 87%, and 97%. The difference in sensitivity between PET/CT and PET/MRI was significant (P = 0.023). The level of confidence regarding liver lesions larger than 1 cm in diameter was significantly higher in PET/MRI than in PET/CT (P = 0.046). Accuracy values (area under the receiver-operating-characteristic curve) for PET/CT, Gd-EOB-DTPA-enhanced MRI, PET/MRI in reader 1, and PET/MRI in reader 2 were 0.85, 0.94, 0.92, and 0.96, respectively.

Conclusion: The sensitivity of Gd-EOB-DTPA-enhanced MRI and PET/MRI in the detection of liver metastases is higher than that of PET/CT. Diagnostic confidence was significantly better with PET/MRI than with PET/CT regarding lesions larger than 1 cm in diameter. Compared with Gd-EOB-DTPA-enhanced MRI, PET/MRI resulted in a nonsignificant increase in sensitivity and diagnostic confidence.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media
  • Female
  • Fluorodeoxyglucose F18*
  • Gadolinium DTPA*
  • Humans
  • Image Processing, Computer-Assisted
  • Liver / diagnostic imaging
  • Liver / pathology
  • Liver / surgery
  • Liver Neoplasms / diagnostic imaging*
  • Liver Neoplasms / pathology
  • Liver Neoplasms / secondary*
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Observer Variation
  • Positron-Emission Tomography
  • Radiopharmaceuticals*
  • Reference Standards
  • Reproducibility of Results
  • Retrospective Studies
  • Tomography, Emission-Computed

Substances

  • Contrast Media
  • Radiopharmaceuticals
  • gadolinium ethoxybenzyl DTPA
  • Fluorodeoxyglucose F18
  • Gadolinium DTPA