Format

Send to

Choose Destination
Acta Orthop. 2009 Apr;80(2):245-50. doi: 10.3109/17453670902947457.

Sonication is superior to scraping for retrieval of bacteria in biofilm on titanium and steel surfaces in vitro.

Author information

1
Department of Orthopaedic Surgery, St Olav's University Hospital, Trondheim, Norway. geir.bjerkan@ntnu.no

Abstract

BACKGROUND AND PURPOSE:

Low-virulence implant infections are characterized by bacterial colonization of the implant with subsequent biofilm formation. In these cases, soft tissue biopsies often prove to be culture negative. Consequently, detachment of the causative adherent bacteria is crucial for correct microbiological diagnosis. Using an in vitro model, we compared 4 methods of biofilm sampling from metal surfaces.

METHODS:

Discs of titanium and steel were incubated in the presence of Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis, and Propionibacterium acnes in Mueller Hinton broth. Non-adherent bacteria were removed by repeated rinsing of the discs. 10 parallels of each disc were subjected to 1 of 4 methods for bacterial recovery: (A) sonication of the discs, (B) scraping of the discs using surgical blades followed by streaking of the blades onto agar plates, (C) scraping of the discs followed by vortex mixing of the surgical blades, and (D) scraping of the discs followed by sonication of the surgical blades. Quantitative bacterial cultures were performed for each sampling method.

RESULTS:

With the exception of S. epidermidis on steel, sonication efficiently and reliably dislodged biofilm bacteria. The scraping methods employed did not detach bacteria embedded in biofilm.

INTERPRETATION:

Scraping of metal surfaces is not an adequate method for sampling of biofilm bacteria in vitro.

PMID:
19404811
PMCID:
PMC2823171
DOI:
10.3109/17453670902947457
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Taylor & Francis Icon for PubMed Central
Loading ...