Format

Send to

Choose Destination
See comment in PubMed Commons below
Arch Phys Med Rehabil. 2008 Dec;89(12):2354-9. doi: 10.1016/j.apmr.2008.05.021. Epub 2008 Nov 1.

Six-minute walk test in persons with transtibial amputation.

Author information

1
School of Physical Therapy, Texas Woman's University, Dallas, TX 75231, USA. slin@twu.edu

Abstract

OBJECTIVE:

This study was to report the within-day test-retest reliability and the measurement properties of the six-minute walk test (6MWT) in persons with lower-limb (transtibial) amputation.

DESIGN:

Test-retest study design.

SETTING:

University research laboratory.

PARTICIPANTS:

Subjects (N=13) with transtibial amputation (9 men and 4 women; mean age, 46 y).

INTERVENTIONS:

Three trials of the 6MWT were conducted within 1 day with 20 to 30 minutes of rest between consecutive trials. Timed Up & Go (TUG) test and timed one-leg balance tests were conducted on another day.

MAIN OUTCOME MEASURES:

(1) Distance, heart rate, symptoms and signs of exercise intolerance during the walk test, (2) times of the TUG test and the one-leg balance test.

RESULTS:

The intraclass correlation coefficient (ICC3,1) value was .94. Bland and Altman graphs showed no systemic variations between trials and a small learning effect. The peak heart rate approximated 72% to 78% of the age-predicted maximal heart rate. Moderate degrees of correlation were observed in: (1) the 6MWT versus the TUG test (r=-.76, P<.05), and (2) the 6MWT versus the timed prosthetic-leg stance (with eyes open: r=.63, P<.05; with eyes closed: r=.61, P<.05).

CONCLUSIONS:

These findings suggest that the 6MWT could be considered as a reliable measure of functional capacity, involves a moderate degree of exercise intensity, and is related in a moderate degree to postural control abilities in persons with transtibial amputation.

PMID:
18976979
DOI:
10.1016/j.apmr.2008.05.021
[Indexed for MEDLINE]