Biologicals. 2008 Sep;36(5):308-14. doi: 10.1016/j.biologicals.2008.05.001. Epub 2008 Jul 9.

Development and validation of an ATP method for rapid estimation of viable units in lyophilised BCG Danish 1331 vaccine.

Author information

1
Quality Control Department, Statens Serum Institut, 5 Artillerivej, Copenhagen S, Denmark. sej@ssi.dk

Abstract

An assay for quantifying viability in BCG vaccine by determining intracellular ATP content was developed and validated. ATP content was determined by measuring bioluminescence in the presence of luciferin/luciferase. During development and validation the ATP method was compared to the conventional viable count method. A key step to obtain correlation between ATP content and CFU was found to be a period of pre-incubation in a growth medium before ATP determination. During the validation, the robustness, linearity, accuracy, precision, and range were studied. The method validation study showed that the method applied was robust and applicable to determine ATP content in lyophilised BCG for estimating viability in the BCG samples. By comparison with a conventional viable count method, a high correlation between ATP content and the viable count was found; this relationship can be applied in routine quality control to estimate viable count from the ATP content determined in a sample.

[Indexed for MEDLINE]