Format

Send to

Choose Destination
See comment in PubMed Commons below
J Thorac Cardiovasc Surg. 2008 Jun;135(6):1297-305. doi: 10.1016/j.jtcvs.2008.02.026. Epub 2008 May 5.

Impact of left atrial volume reduction concomitant with atrial fibrillation surgery on left atrial geometry and mechanical function.

Author information

1
Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, Kyoto, Japan.

Abstract

OBJECTIVE:

Left atrial geometry and mechanical functions exert a profound effect on left ventricular filling and overall cardiovascular performance. We sought to investigate the perioperative factors that influence left atrial geometry and mechanical functions after the Maze procedure in patients with refractory atrial fibrillation and left atrial enlargement.

METHODS:

Seventy-four patients with atrial fibrillation and left atrial enlargement (diameter > or = 60 mm) underwent the Maze procedure in association with mitral valve surgery. The maximum left atrial volume and left atrial mechanical functions (booster pump, reservoir, and conduit function [%]) were calculated from the left atrial volume-cardiac cycle curves obtained by magnetic resonance imaging. A stepwise multiple regression analysis was performed to determine the independent variables that influenced the postoperative left atrial geometry and function.

RESULTS:

The multivariate analysis showed that left atrial reduction surgery concomitant with the Maze procedure and the postoperative maintenance of sinus rhythm were predominant independent variables for postoperative left atrial geometry and mechanical functions. Among the 58 patients who recovered sinus rhythm, the postoperative left atrial geometry and function were compared between patients with (VR group) and without (control group) left atrial volume reduction. At a mean follow-up period of 13.8 months, sinus rhythm recovery rate was better (85% vs 68%, P < .05) in the VR group and maximum left atrial volume was less (116 +/- 25 mL vs 287 +/- 73 mL, P < .001) than in the control group. The maximum left atrial volume reduced with time only in the VR group (reverse remodeling). Postoperative booster pump and reservoir function in the VR group were better than in the control group (25% +/- 6% vs 11% +/- 4% and 34% +/- 7% vs 16% +/- 4%, respectively, P < .001), whereas the conduit function in the VR group was lower than in the control group, indicating that the improvement of the booster pump and reservoir function compensated for the conduit function to left ventricular filling.

CONCLUSION:

Left atrial reduction concomitant with the Maze procedure helped restore both contraction (booster pump) and compliance (reservoir) of the left atrium and facilitated left atrial reverse remolding. Left atrial volume reduction and postoperative maintenance of sinus rhythm may be desirable in patients with refractory AF and left atrial enlargement.

PMID:
18544375
DOI:
10.1016/j.jtcvs.2008.02.026
[Indexed for MEDLINE]
Free full text
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Support Center