J Nucl Med. 2008 Mar;49(3):453-61. doi: 10.2967/jnumed.107.048009. Epub 2008 Feb 20.

18F-labeled BBN-RGD heterodimer for prostate cancer imaging.

Author information

1
Molecular Imaging Program at Stanford, Department of Radiology, Biophysics, and Bio-X Program, Stanford University School of Medicine, Stanford, California 94305-5484, USA.

Abstract

Both bombesin (BBN) analogs and cyclic RGD peptides have been suitably radiolabeled for prostate cancer imaging. However, the limited expression of gastrin-releasing peptide receptor (GRPR) and integrin alpha(v)beta(3) as well as unfavorable in vivo kinetics limited further applications of these imaging agents. We hypothesize that a peptide ligand recognizing both GRPR and integrin will be advantageous because of its dual-receptor-targeting ability.

METHODS:

A BBN-RGD heterodimer was synthesized from bombesin(7-14) and c(RGDyK) through a glutamate linker and then labeled with (18)F via the N-succinimidyl-4-(18)F-fluorobenzoate ((18)F-SFB) prosthetic group. The receptor-binding characteristics and tumor-targeting efficacy of (18)F-FB-BBN-RGD were tested in vitro and in vivo.

RESULTS:

FB-BBN-RGD had comparable integrin alpha(v)beta(3)-binding affinity with c(RGDyK) and comparable GRPR-binding affinity with BBN(7-14). (18)F-FB-BBN-RGD had significantly higher tumor uptake compared with monomeric RGD and monomeric BBN peptide tracer analogs at all time points examined. The PC-3 tumor uptake of (18)F-FB-BBN-RGD was inhibited only partially in the presence of an excess amount of unlabeled BBN(7-14) or c(RGDyK) but was blocked completely in the presence of both BBN(7-14) and c(RGDyK). Compared with (18)F-FB-BBN and (18)F-FB-RGD, (18)F-FB-BBN-RGD also had improved pharmacokinetics, resulting in a significantly higher imaging quality.

CONCLUSION:

Dual integrin alpha(v)beta(3) and GRPR recognition showed significantly improved tumor-targeting efficacy and pharmacokinetics compared with (18)F-labeled RGD and BBN analogs. The same heterodimeric ligand design may also be applicable to other receptor system combinations and other imaging modalities.

PMID:
18287274
DOI:
10.2967/jnumed.107.048009
[Indexed for MEDLINE]