Authentication of Kalix (N.E. Sweden) vendace caviar using inductively coupled plasma-based analytical techniques: evaluation of different approaches

Anal Chim Acta. 2007 Feb 5;583(2):310-8. doi: 10.1016/j.aca.2006.10.038. Epub 2006 Nov 6.

Abstract

Different analytical approaches for origin differentiation between vendace and whitefish caviars from brackish- and freshwaters were tested using inductively coupled plasma double focusing sector field mass spectrometry (ICP-SFMS) and multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). These approaches involve identifying differences in elemental concentrations or sample-specific isotopic composition (Sr and Os) variations. Concentrations of 72 elements were determined by ICP-SFMS following microwave-assisted digestion in vendace and whitefish caviar samples from Sweden (from both brackish and freshwater), Finland and USA, as well as in unprocessed vendace roe and salt used in caviar production. This data set allows identification of elements whose contents in caviar can be affected by salt addition as well as by contamination during production and packaging. Long-term method reproducibility was assessed for all analytes based on replicate caviar preparations/analyses and variations in element concentrations in caviar from different harvests were evaluated. The greatest utility for differentiation was demonstrated for elements with varying concentrations between brackish and freshwaters (e.g. As, Br, Sr). Elemental ratios, specifically Sr/Ca, Sr/Mg and Sr/Ba, are especially useful for authentication of vendace caviar processed from brackish water roe, due to the significant differences between caviar from different sources, limited between-harvest variations and relatively high concentrations in samples, allowing precise determination by modern analytical instrumentation. Variations in the 87Sr/86Sr ratio for vendace caviar from different harvests (on the order of 0.05-0.1%) is at least 10-fold less than differences between caviar processed from brackish and freshwater roe. Hence, Sr isotope ratio measurements (either by ICP-SFMS or by MC-ICP-MS) have great potential for origin differentiation. On the contrary, it was impossible to differentiate between Swedish caviar processed from brackish water roe and Finnish freshwater caviar based solely on 187Os/188Os ratios.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Eggs / analysis*
  • Fish Products / analysis
  • Food Analysis / methods*
  • Fresh Water / analysis
  • Mass Spectrometry / methods
  • Salmonidae*
  • Sweden