Format

Send to

Choose Destination
Pediatrics. 2006 Nov;118 Suppl 2:S177-86.

Overcoming barriers to oxygen saturation targeting.

Author information

1
Section of Neonatology, Department of Pediatrics, Children's Mercy Hospitals and Clinics, 2401 Gillham Rd, Kansas City, MO 64108, USA.

Abstract

OBJECTIVE:

To reduce hyperoxia in very low birth weight infants who receive supplemental oxygen, the Children's Mercy Hospital neonatal respiratory quality improvement committee introduced the potentially better practice of oxygen saturation targeting and identified strategies to overcome barriers to implementation of this practice.

METHODS:

Using rapid-cycle quality improvement projects, this center adapted an oxygen saturation targeting protocol and tracked hourly oxygen saturation as measured by pulse oximetry in very low birth weight infants who received supplemental oxygen.

RESULTS:

The percentage of time in the range of 90% to 94% of oxygen saturation as measured by pulse oximetry increased from 20% to an average of 35% after implementation of the protocol. The percentage of time with oxygen saturation as measured by pulse oximetry >98% dropped from 30% to an average of 5% to 10%.

CONCLUSIONS:

A well-planned strategy for implementing oxygen saturation targeting can result in a sustained change in clinical practice as well as change in the culture of the NICU regarding the use of oxygen.

PMID:
17079621
DOI:
10.1542/peds.2006-0913P
[Indexed for MEDLINE]

Supplemental Content

Full text links

Icon for HighWire
Loading ...
Support Center