Dent Mater. 2007 Aug;23(8):911-20. Epub 2006 Oct 6.

Shrinkage stress in light-cured composite resins: influence of material and photoactivation mode.

Author information

1
Laboratoire des Sciences du GĂ©nie Chimique, UPR 6811, INPL, ENSIC, 1, rue Grandville, BP 451 F-54.001 Nancy Cedex, France. charton.christophe@wanadoo.fr

Abstract

OBJECTIVES:

The aim of this study was to record the effect of composite type and photoactivation mode on the stresses resulting from polymerization of five established composite resins: packable (Solitaire, Solitaire 2), micro-hybrid (Aelitefil, Z100) and hybrid (Clearfil AP-X).

METHODS:

A mechanical testing machine was used to record the polymerization contraction stress (MPa) of cylindrical composite specimens (d=5mm; h=2mm; C-factor=1.25) at 0.1s intervals over a period of 400s. The samples were photopolymerized using a halogen light curing device under two types of light exposure: group 1, Standard (800mW.cm(-2)x60s); group 2, Exponential (logarithmic increase from 150 to 800mW.cm(-2) over 15s+800mW.cm(-2)x45s). The stress rate (SR: slope(MPa>0-60s)) and the maximum shrinkage stress (MSS: MPa(400s)) of each material (five replications) were statistically analysed by one-way ANOVA/Scheffe's test and Pearson's correlation procedure (alpha=0.05). Finally, Student's t-test (two matched series) enabled the assessment of the effect of the irradiation method on the results.

RESULTS:

For group 1, in decreasing order, the MSS was 1.51+/-0.07MPa (Solitaire) statistically equivalent to 1.45+/-0.06MPa (Aelitefil), 1.29+/-0.08MPa (Solitaire 2), and 1.04+/-0.03MPa (Z100) statistically equivalent to 0.92+/-0.05MPa (Clearfil AP-X). Z100 showed the highest SR (0.045+/-6x10(-3)) and Solitaire, the lowest (0.017+/-2x10(-3)). There was no correlation between SR and MSS (r<-0.33, p<0.05). For group 2, the MSS and SR values were distributed in a similar way to those from group 1. There was a negative correlation between SR and MSS (r<-0.43 and p<0.01). The exponential ramp successfully reduced the MSS (-3.9%) and SR (-11%) values.

SIGNIFICANCE:

There is no relationship between composite resin type, stress rate and shrinkage stress levels. The slower stress rate development, resulting from ramped light intensity, helped slightly to reduce the maximum polymerization stress.