J Endod. 2006 May;32(5):421-4.

Effect of blood contamination on retention characteristics of MTA when mixed with different liquids.

Author information

1
Department of Endodontics, Lakenheath Air Base, UK.

Abstract

Simulated furcation perforations were repaired with and without blood contamination utilizing tooth-colored mineral trioxide aggregrate (MTA) mixed with either MTA liquid (sterile water), lidocaine, or saline. Samples underwent Instron testing at either 24 or 72 hours and at 7 days. Data were analyzed using a 3-way ANOVA and post-hoc testing using Turkey's true test for significance. All of the 72-hour samples displayed significantly greater resistance to displacement than the 24-hour samples. All of the 7-day samples displayed significantly greater resistance to displacement than the 24-hour and 72-hour samples. Non-contaminated samples displayed significantly greater resistance to displacement than their blood-contaminated counterparts at 7 days. Non-contaminated samples mixed with sterile water, lidocaine, or saline performed similarly at all time periods. Allowing tooth-colored MTA to set undisturbed for 72 hours or longer prior to placement of a coronal restoration may decrease the chance of MTA displacement in furcation perforation repairs.

PMID:
16631840
DOI:
10.1016/j.joen.2005.09.007
[Indexed for MEDLINE]