[Effect of prism length on the notchless triangular prism fracture toughness test]

Nihon Hotetsu Shika Gakkai Zasshi. 2005 Apr;49(2):253-62. doi: 10.2186/jjps.49.253.
[Article in Japanese]

Abstract

Purpose: The purpose of this study was to clarify the effect of holding condition with different prism length on the Notchless Triangular Prism (NTP) fracture toughness test and to define the prism length as a measuring condition.

Methods: Two kinds of NTP prism (ceramic and composite resin) were fabricated by CAD/CAM and each prism was adjusted to one of three lengths (8.0 mm, 12.0 mm, 16.0 mm). NTP was conducted for prism specimens made under six different conditions. The displacement of prism specimen holder gap (Delta d) and maximum fracture load (Pmax) were recorded and then a fractogram of each prism was inspected by SEM.

Results: Inclined stable fracture propagation was observed on the fractogram of the 8.0-mm prism. Both Delta d and Pmax of the 8.0-mm prism were significantly higher than those of the other lengths.

Conclusions: A prism length of at least 12.0 mm is needed for the NTP because the 8.0-mm prism did not have a sufficient holding condition. The fracture toughness of the ceramic (3.68+/-0.09 MPa.m(1/2)) was significantly higher than that of the composite resin (2.38+/-0.20 MPa.m(1/2)).

Publication types

  • English Abstract

MeSH terms

  • Ceramics / standards*
  • Composite Resins / standards*
  • Hardness Tests*
  • Stress, Mechanical

Substances

  • Composite Resins