J Cataract Refract Surg. 2005 Mar;31(3):636-9.

Surface and Orbscan II slit-scanning elevation topography in circumscribed posterior keratoconus.

Author information

1
Centro Oftalmol├│gico Daniel E. Charles, Buenos Aires, Argentina. ncharles@topmail.com.ar

Abstract

We used an Orbscan II topography system (Bausch & Lomb) to study anterior and posterior surface abnormalities, keratometry, and topographic pachymetry in a patient with circumscribed posterior keratoconus. This system clearly showed a marked localized paracentral annular elevation in the posterior corneal surface that corresponded to an abrupt decrease in thickness and a slightly localized anterior surface bulge in the anterior float.