Format

Send to

Choose Destination
See comment in PubMed Commons below
Anal Chem. 2004 Dec 1;76(23):7028-38.

LC-MS/MS analysis of peptides with methanol as organic modifier: improved limits of detection.

Author information

  • 1The Charles B. Stout Neuroscience Mass Spectrometry Laboratory and the Department of Neurology, University of Tennessee Health Science Center, Memphis, Tennessee 38163, USA. fgiorgianni@utmem.edu

Abstract

With the advent of soft ionization methods such as MALDI and ESI, mass spectrometry has become the most important technique for the analysis of proteins and peptides. ESI-MS is often preceded by separation of the peptide sample by reversed-phase liquid chromatography (LC). Acetonitrile (ACN) is the most commonly employed organic solvent in LC-ESI-MS analysis of peptides. In this report, we demonstrate that the use of methanol (MeOH) as the organic modifier improves the detection limits for analysis of peptide mixtures such as those found in tryptic digests of proteins. A nanoLC-ESI-quadrupole ion trap instrument (LCQ Deca, ThermoFinnigan) was used to analyze peptide standards, protein digests of known concentrations, and tryptic digests of 2-DGE-separated proteins. MeOH displayed excellent chromatographic performance (separation and sensitivity), and shorter gradient times were possible for chromatographic separation with MeOH versus ACN. Sensitivity levels of a few hundred attomoles were achieved with MeOH; those levels could not be achieved with ACN. In addition, MeOH-based nanoLC-MS/MS yielded superior results for the analysis of digests of 2-DGE-separated proteins. For the 14 protein spots analyzed, the success rate of protein identification with MeOH-based nanoLC-ESI-MS/MS was 100%, with multiple proteins identified in several of the spots. In contrast, ACN-based procedure failed to identify any proteins in 21% of the spots and overall identified 33% fewer proteins than the MeOH-based procedure. In summary, higher sensitivity and shorter gradient times make MeOH an excellent organic modifier for the use in nanoLC-ESI-MS/MS analysis of peptides.

PMID:
15571356
DOI:
10.1021/ac0493368
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for American Chemical Society
    Loading ...
    Support Center