USPIO-enhanced MRI for preoperative staging of gynecological pelvic tumors: preliminary results

Eur Radiol. 2004 Jun;14(6):937-44. doi: 10.1007/s00330-004-2258-8. Epub 2004 Feb 26.

Abstract

The aim of this study was to assess nodal enhancement with ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging (MRI) during preoperative staging of gynecological pelvic tumors within the same imaging session for the primary tumor. Pelvic MRI was performed 18-28 h after intravenous infusion of USPIO (Combidex/Sinerem, 2.6 mg Fe/kg body weight) in 13 women (mean age 51 years) scheduled for surgery for biopsy proven ( n=11) or clinically suspected ( n=2) uterine carcinoma. Axial T1-weighted spin-echo (SE), T2-weighted fast SE (FSE; with fat saturation), fast spoiled gradient-recalled (FSPGR) echo, sagittal and oblique T2-weighted FSE sequences were acquired on a 1.5-T system. Lymph nodes were prospectively staged using standard criteria, i.e., size and shape, as well as USPIO enhancement. Results were correlated with histology findings. MRI correctly staged all primary uterine tumors. In one case, the preoperative diagnosis of stage IV switched the therapeutic approach to radiochemotherapy. Ninety-one (86 benign, 5 malignant) of the histologically characterized nodes could be correlated with their MRI counterparts. One node was false positive; three micrometastases greater than 5 mm and one 5-mm metastasis were missed. On a nodal basis, the sensitivity score was 0.33 and the specificity score, 0.99. On a patient basis, the sensitivity score was 0.25 and the specificity score, 0.80. Our preliminary results indicate that USPIO-enhanced pelvic MRI for preoperative nodal assessment is feasible within one imaging session for primary tumors and that it has a high specificity. However, the low sensitivity in the present study is a limitation for the clinical application of this technique.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Dextrans
  • Feasibility Studies
  • Female
  • Ferrosoferric Oxide
  • Genital Neoplasms, Female / diagnosis*
  • Genital Neoplasms, Female / surgery
  • Humans
  • Image Enhancement / methods*
  • Iron / pharmacology*
  • Lymph Nodes / pathology
  • Magnetic Resonance Imaging / methods*
  • Magnetite Nanoparticles
  • Middle Aged
  • Neoplasm Staging / methods*
  • Oxides / pharmacology*
  • Pelvic Neoplasms / diagnosis*
  • Pelvic Neoplasms / surgery
  • Polygonatum
  • Preoperative Care
  • Sensitivity and Specificity
  • Uterine Cervical Neoplasms / diagnosis
  • Uterine Neoplasms / diagnosis
  • Uterine Neoplasms / surgery

Substances

  • Dextrans
  • Magnetite Nanoparticles
  • Oxides
  • ferumoxtran-10
  • Iron
  • Ferrosoferric Oxide