Format

Send to

Choose Destination
See comment in PubMed Commons below
Calcif Tissue Int. 2004 May;74(5):437-47. Epub 2004 Feb 17.

Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity.

Author information

1
Department of Archaeology, and the Joint Injury and Arthritis Research Group, University of Calgary, T2N 4N1, Calgary, Alberta, Canada.

Abstract

Cortical bone is perforated by a network of canals that have a significant impact upon its material properties. Microcomputed tomography offers the possibility of noninvasively visualizing and quantifying cortical pores in both two and three dimensions. Establishing how two-dimensional (2D) microcomputed tomographic (microCT) analysis compares with conventional methods for analyzing cortical porosity is an important prerequisite for the wider adoption of this technique and the development of three-dimensional (3D) analysis. Therefore, we compared porosity-related parameters from 2D microcomputed tomographic images with those from matching microradiographic sections. Samples from five human femora were scanned at a 10-microm resolution and then sequentially sectioned and microradiographed. An average of eight image pairs were produced from each femur (total, n = 41). The repeatability and comparability of the two techniques was assessed for three parameters; cortical porosity (%), mean pore area (microm(2)), and pore density (pores/mm(2)). For repeatability, no significant difference ( P > 0.05) was found between the two methods for cortical porosity and mean pore area; however, pore density differed significantly ( P < 0.001). For comparability, the bias (+/- error) between the methods was found to be 0.51% (+/-0.31%) for cortical porosity and -155 microm(2) (+/-293 microm(2)) for mean pore area. The bias for pore density was dependent upon measurement size with microcomputed tomographic images having 14% (+/-9.3%) fewer pores per millimeter squared. The qualitative and quantitative similarities between the two techniques demonstrated the utility of 2D microcomputed tomographic for cortical porosity analysis. However, the relatively poor results for pore density revealed that a higher resolution (<10 microm) is needed to consistently visualize all cortical pores in human bone.

PMID:
14961208
DOI:
10.1007/s00223-003-0071-z
[Indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Springer
    Loading ...
    Support Center