Format

Send to

Choose Destination
See comment in PubMed Commons below
Technol Cancer Res Treat. 2003 Dec;2(6):563-9.

Comparison of water and lipid content measurements using diffuse optical spectroscopy and MRI in emulsion phantoms.

Author information

1
Laser Microbeam and Medical Program, Beckman Laser Institute, University of California Irvine, Irvine, California 92612, USA.

Abstract

We present a quantitative comparison of lipid and water signals obtained from broadband Diffuse Optical Spectroscopy (DOS) and Magnetic Resonance Imaging (MRI). DOS and MRI measurements were performed on an identical set of emulsion phantoms that were composed of different water/soybean oil fractions. Absolute concentrations of water and lipid ranging from 35-94% and 63-6%, respectively were calculated from quantitative broadband near-infrared (NIR) absorption spectra (650-1000 nm). MR images of fat and water were separated using the three-point Dixon technique. DOS and MRI measured water and lipid were highly correlated (R(2) = 0.98 and R(2) = 0.99, respectively) suggesting that these techniques are complementary over a broad range of physiologically relevant water and lipid values. In addition, comparison of DOS derived concentrations to the MRI "gold standard" technique validates our quantitation approach and permits estimation of DOS accuracy and sensitivity in vivo.

PMID:
14640767
DOI:
10.1177/153303460300200608
[Indexed for MEDLINE]