Environ Health Perspect. 2003 Oct;111(13):1595-600.

Measurement of brevetoxin levels by radioimmunoassay of blood collection cards after acute, long-term, and low-dose exposure in mice.

Author information

  • 1Marine Biotoxins Program, Center for Coastal Environmental Health and Biomolecular Research, National Oceanic and Atmospheric Administration, National Ocean Service, Charleston, South Carolina 29412, USA.

Abstract

We developed a radioimmunoassay (RIA) using a sheep anti-brevetoxin antiserum to evaluate detection of brevetoxin on blood collection cards from mice treated with the brevetoxin congener PbTx-3. The RIA has high affinity for PbTx-3 [half-maximal effective concentration (EC(50)) +/- SE = 1.2 +/- 0.2 nM; n = 10] and recognizes both type 1 and type 2 brevetoxins, but not ciguatoxin. Direct comparison of the RIA with a radiolabeled [(3)H]-PbTx-3 receptor-binding assay (RBA) revealed excellent sensitivity, congener selectivity, and minimal interference from blood matrix. We first analyzed blood samples from an acute time course exposure, using a maximal nonlethal dose [180 microg/kg body weight (bw)] for 0.5, 1, 2, 4, and 24 hr. Mean blood brevetoxin levels were 36 nM at 30 min and stayed above 20 nM during the 1-4 hr time points. We next analyzed blood brevetoxin levels after longer exposure (0.5, 1, 2, 3, 4, or 7 days). Mean blood brevetoxin levels were 26.0 nM at 0.5 days, decreased to 8.2 nM at 1.0 day, and maintained a significant level (p < 0.05) of 1.3 nM at day 2. We next determined the lowest measurable dose using increasing concentrations of PbTx-3 (10-300 micro g/kg bw). Analysis of the blood samples at 60 min revealed a linear relationship between administered and internal doses (r(2) = 0.993). All doses of brevetoxin administered were detectable at 1 hr, with significant levels found for the lowest administered dose of 10 micro g/kg bw--a dose that was 10-fold lower than the lowest observable effect level. This RIA provides an optimal first-tier detection of brevetoxin from blood collection cards and, used in combination with the RBA and liquid chromatography-mass spectrometry, should provide a complete panel of methods to biomonitor brevetoxin exposure.

PMID:
14527838
PMCID:
PMC1241680
[PubMed - indexed for MEDLINE]
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for PubMed Central
    Loading ...
    Support Center