Format

Send to

Choose Destination
See comment in PubMed Commons below
Am J Clin Pathol. 2003 Mar;119(3):432-8.

A computer-based intervention for improving the appropriateness of antiepileptic drug level monitoring.

Author information

  • 1Department of Pathology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA.

Abstract

We designed and implemented 2 automated, computerized screens for use at the time of antiepileptic drug (AED) test order entry to improve appropriateness by reminding physicians when a potentially redundant test was ordered and providing common indications for monitoring and pharmacokinetics of the specific AED. All computerized orders for inpatient serum AED levels during two 3-month periods were included in the study. During the 3-month period after implementation of the automated intervention, 13% of all AED tests ordered were canceled following computerized reminders. For orders appearing redundant, the cancellation rate was 27%. For nonredundant orders, 4% were canceled when information on specific AED monitoring and pharmacokinetics was provided. The cancellation rate was sustained after 4 years. There has been a 19.5% decrease in total AED testing volume since implementation of this intervention, despite a 19.3% increase in overall chemistry test volume. Inappropriateness owing to repeated testing before pharmacologic steady state was reached decreased from 54% of all AED orders to 14.6%. A simple, automated, activity-based intervention targeting a specific test-ordering behavior effectively reduced inappropriate laboratory testing. The sustained benefit supports the idea that computerized interventions may durably affect physician behavior. Computerized delivery of such evidence-based boundary guidelines can help narrow the gap between evidence and practice.

PMID:
12645347
[PubMed - indexed for MEDLINE]
Free full text
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for HighWire
    Loading ...
    Support Center