Clin Chim Acta. 1976 Mar 15;67(3):299-306.

Measurement of angiotensin II in human plasma: technical modifications and practical experience.

Abstract

This paper presents our experience in measurement of plasma angiotensin II concentration according to the method described by Düsterdieck, G. and McElwee, G. (1971) Eur. J. Clin. Invest. 2, 32-38. Certain technical modifications of the procedure have been worked out. For each individual plasma sample, the recovery across extraction and elution steps is determined by addition of radio-iodinated angiotensin II. A time-saving recycling elution procedure is described. Evidence for the clinical applicability of the modified method is presented.