Simple method for assaying colistin methanesulfonate in plasma and urine using high-performance liquid chromatography

Antimicrob Agents Chemother. 2002 Oct;46(10):3304-7. doi: 10.1128/AAC.46.10.3304-3307.2002.

Abstract

A simple and sensitive high-performance liquid chromatographic method is described for the determination of colistimethate sodium in plasma and urine. The accuracy and reproducibility was within 10.1 and 11.2% with rat plasma and urine, respectively. Several commonly coadministered antibacterial agents do not interfere with the assay.

Publication types

  • Evaluation Study

MeSH terms

  • Animals
  • Chromatography, High Pressure Liquid / methods
  • Colistin / analogs & derivatives*
  • Colistin / blood*
  • Colistin / urine*
  • Rats
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • colistinmethanesulfonic acid
  • Colistin