Format

Send to

Choose Destination
Pflugers Arch. 2002 May;444(1-2):99-106. Epub 2002 Feb 20.

Voltage-dependent changes in specific membrane capacitance caused by prestin, the outer hair cell lateral membrane motor.

Author information

1
Section of Otolaryngology, Yale University School of Medicine, 333 Cedar St., New Haven, CT 06510 USA. joseph.santos-sacchi@yale.edu

Abstract

In the outer hair cell (OHC), membrane capacitance principally derives from two components - that associated with lateral membrane sensor/motor charge movement, and that proportional to the membrane surface area (C(sa)). We used measures of membrane capacitance to test a model hypothesis that OHC lateral membrane molecular motors, recently identified as the protein prestin, fluctuate between two area states. By measuring membrane capacitance in native OHCs or prestin-transfected HEK cells at extreme voltages (+/-200 mV) where motor-derived charge movement is small or absent, we observed that C(sa) depends on the state of the motors, or correspondingly on membrane voltage. Deiters cells or control HEK cells, which lack motors, do not show this dependence. We modeled the voltage-dependent change in C(sa) as a Boltzmann process with the same parameters that describe the charge movement of the motors' voltage sensors. C(sa) is 3.28+/-0.75 pF (mean +/-SD; n=23) larger during extreme hyperpolarization, and the number of motors in OHCs and prestin-transfected HEK cells correlates with the magnitude of Delta C(sa)( r=0.78). Although these data are consistent with the area motor model, the corresponding area change, assuming 0.5 microF/cm(2) under constant membrane thickness, is unphysiologically large, and indicates that the capacitance change must result from changes not only in lateral membrane area but also specific capacitance. Thus, we conclude that a conformational change in the lateral membrane motor, prestin, additionally alters the dielectric constant and/or thickness of the lateral plasma membrane.

PMID:
11976921
DOI:
10.1007/s00424-002-0804-2
[Indexed for MEDLINE]

Supplemental Content

Full text links

Icon for Springer
Loading ...
Support Center