Zhonghua Shao Shang Za Zhi. 2000 Jun;16(3):163-5.

[The role of ozone solution on debridement and sterilization of burn wound].

[Article in Chinese]

Author information

1
Department of Burns, The Third Municipal Hospital of Wu Han, Wu Han 430037, P.R. China.

Abstract

OBJECTIVE:

To observe the role of ozone solution on debridement and sterilization of burn wound.

METHODS:

In vitro sterilizing effect on common isolated bacteria from burn wound and debridement and sterilization effects on burn wound of ozone disinfectant (ozone solution) were studied.

RESULTS:

All the bacteria tested were killed in vitro by ozone solution. In addition, when ozone solution was applied on burn wound, its clearance rate of bacteria was 94.5% and the clinical effective rate was 97.1%.

CONCLUSION:

Ozone is low in cost and high in effect which might be used as an agent for burn wound disinfection.