Format

Send to

Choose Destination
J Neuroimaging. 2001 Oct;11(4):363-8.

Comparison of transcranial color-coded sonography and magnetic resonance angiography in acute ischemic stroke.

Author information

1
Department of Neurology, Shin Kong WHS Memorial Hospital, 95 Wen Chang Road, Shih Lin, Taipei, Taiwan. limingmd@ms28.hinet.net

Abstract

BACKGROUND AND PURPOSE:

This study was designed to assess the accuracy of transcranial color-coded sonography (TCCS) as compared to magnetic resonance angiography (MRA) for detecting intracranial arterial stenosis in patients with acute cerebral ischemia.

METHODS:

The authors prospectively identified 120 consecutive patients admitted with acute ischemic stroke and performed both TCCS and MRA with a mean interval of 1 day. TCCS data (sampling depth, peak systolic and end diastolic angle-corrected velocity, mean angle-corrected velocity, and pulsatility index) for middle cerebral arteries (MCAs) were compared to MRA data and classified into 4 grades: normal (grade 1): normal caliber and signal; mild stenosis (grade 2): irregular lumen with reduced signal; severe stenosis (grade 3): absent signal in the stenotic segment (flow gap) and reconstituted distal signal; and possible occlusion (grade 4): absent signal. The cutoffs were chosen to maximize diagnostic accuracy.

RESULTS:

Interobserver agreement for MRA grading resulted in a weighted-kappa value of 0.776. The rate of poor temporal window was 37% (89/240). Doppler signals were obtained in 135 vessels, and the angle-corrected velocities (peak systolic, end diastolic, mean) were significantly different (P = .001, P = .006, and P < .001) among the MRA grades: grade 1 (100, 47, 68 cm/s), grade 2 (171, 72, 110 cm/s), grade 3 (226, 79, 134 cm/s), grade 4 (61, 26, 39 cm/s). Additionally, an angle-corrected MCA peak systolic velocity > or = 120 cm/s correlates with intracranial stenosis on MRA (grade 2 or worse) with high specificity (90.5%; 95% confidence interval = 78.5%-96.8%) and positive predictive value (93.9%) but relatively low sensitivity (66.7%; 95% confidence interval = 61.2%-69.5%) and negative predictive value (55.1%).

CONCLUSION:

Elevated MCA velocities on TCCS correlate with intracranial stenosis detected on MRA. An angle-corrected peak systolic velocity > or = 120 cm/s is highly specific for detecting intracranial stenosis as defined by significant MRA abnormality.

PMID:
11677875
[Indexed for MEDLINE]

Supplemental Content