Invest Radiol. 2000 Jul;35(7):412-9.

Magnetic resonance imaging in patients with central nervous system pathology: a comparison of OptiMARK (Gd-DTPA-BMEA) and Magnevist (Gd-DTPA).

Author information

1
University of Pennsylvania Medical Center, Philadelphia, USA.

Abstract

RATIONALE AND OBJECTIVES:

The objective of the two pivotal phase 3 studies was to evaluate the safety and efficacy of OptiMARK (Gd-DTPA-bis(methoxyethylamide) [Gd-DTPA-BMEA]) compared with Magnevist (Gd-DTPA) in magnetic resonance imaging of the central nervous system.

METHODS:

Two multicenter, randomized, double-blind, parallel group studies were conducted in 395 patients with known or suspected central nervous system pathology. Subjects were randomized to receive a single 0.1 mmol/kg intravenous injection of either Gd-DTPA-BMEA or Gd-DTPA. The safety of Gd-DTPA-BMEA and Gd-DTPA was monitored for up to 72 hours after study drug administration. Precontrast and postcontrast administration magnetic resonance scans were acquired using identical imaging planes and techniques.

RESULTS:

No deaths or unexpected adverse events were reported in either group. A comparison of adverse events by intensity and relation demonstrated no statistically significant differences between the two groups. Gd-DTPA-BMEA and Gd-DTPA were equivalent with respect to confidence in diagnosis, conspicuity, and border delineation.

CONCLUSIONS:

Gd-DTPA-BMEA and Gd-DTPA demonstrated comparable efficacy profiles, and the safety profiles were considered similar.