IEEE Trans Biomed Eng. 2000 Feb;47(2):228-38.

Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study.

Author information

1
Department of Biomedical Engineering and Informatics, University Hospital, UmeƄ, Sweden. Stefan.Karlsson@medtech.umu.se

Abstract

In this paper, we introduce the nonstationary signal analysis methods to analyze the myoelectric (ME) signals during dynamic contractions by estimating the time-dependent spectral moments. The time-frequency analysis methods including the short-time Fourier transform, the Wigner-Ville distribution, the Choi-Williams distribution, and the continuous wavelet transform were compared for estimation accuracy and precision on synthesized and real ME signals. It is found that the estimates provided by the continuous wavelet transform have better accuracy and precision than those obtained with the other time-frequency analysis methods on simulated data sets. In addition, ME signals from four subjects during three different tests (maximum static voluntary contraction, ramp contraction, and repeated isokinetic contractions) were also examined.

PMID:
10721630
DOI:
10.1109/10.821766