Int J Obes Relat Metab Disord. 2000 Feb;24(2):200-5.

Validation of the BOD POD with hydrostatic weighing: influence of body clothing.

Author information

1
Division of Physiology and Metabolism, Departments of Nutrition Sciences and Human Studies, University of Alabama at Birmingham, Birmingham, AL 35294-1250, USA.

Abstract

OBJECTIVE:

Whole body air-displacement plethysmography (BOD POD), a new body composition technique, was validated against hydrodensitometry (UWW) in 67 women wearing a one-piece swimsuit (OP) who represent a wide range of body fatness and age. Additionally, the effect of trapped isothermic air in clothing while in the BOD POD was examined by comparing different clothing schemes (a one-piece swimsuit (OP), two-piece swimsuit (TP), a hospital gown (HG), and a hospital gown previously included in a volume calibration (GC)) in a subset of 25 women.

DESIGN:

Cross-sectional data analysis.

SUBJECTS:

67 healthy Caucasian females.

MEASUREMENTS:

Body density g/cm3 (Db) by BOD POD and UWW.

RESULTS:

In 67 females UWW Db (1.030+/-0.020 g/cm3) was higher (P<0.01) than BOD POD Db (1. 028+/-0.020 g/cm3). This is a difference of 1.0% fat. The R2 was 0. 94, SEE was 0.005 g/cm3 and the regression between Db by UWW and BOD POB did not significantly deviate from the line of identity. In the subset group of 25 subjects, OP Db (1.040+/-0.014 g/cm3) and TP Db (1.040+/-0.014 g/cm3) were significantly lower (P<0.01) than UWW Db (1.044+/-0.014 g/cm3) or a difference of 1.9% fat. The R2 was 0.86 and the SEE was 0.005 g/cm3 and the regression between Db by UWW and both OP and TP did not significantly deviate from the line of identity. HG Db (1.056+/-0.016 g/cm3) and GC Db (1.037+/-0.016 g/cm3) were significantly different (P<0.01) from UWW Db (1.044+/-0. 014 g/cm3). This difference in density translates to a difference of 5.5% and 3.2% fat respectively. The regression between Db by UWW and both HG and GC significantly deviated from the line of identity.

CONCLUSION:

This study supports the use of the BOD POD as a substitute for UWW. However, caution should be made in using the BOD POD if subjects are clothed in anything other than a tight fitting swimsuit.