Format

Send to

Choose Destination
J Manipulative Physiol Ther. 1999 Jan;22(1):4-9.

Intraexaminer and interexaminer reliability of the Gillet test.

Author information

1
Institute for Physical Therapy, Bussum, The Netherlands.

Abstract

OBJECTIVES:

The purpose of this study was to determine the intraexaminer and interexaminer reliability of the Gillet test.

STUDY DESIGN:

In a test-retest study the incidence of asymmetric or symmetric sacroiliac joint motion was investigated with the Gillet test.

METHODS:

Forty-one male subjects volunteered for this study (mean age, 23 +/- 2.24 years). Thirty-eight subjects were examined in the first test procedure, and at least 4 days later 37 subjects were examined again. The subjects were subdivided into symptomatic and asymptomatic groups on the basis of certain criteria.

RESULTS:

To obtain the intraexaminer and interexaminer reliability values, Cohen's kappa, the percentage agreement, bias-adjusted kappa, and prevalence-adjusted bias-adjusted kappa were used. The mean Cohen's kappa did not exceed the value of 0.081. Only the percentage agreement of the symptomatic group did exceed the minimum level of 80%. When kappa was positive, the prevalence-adjusted bias-adjusted kappa was markedly higher than kappa; when kappa was negative, the prevalence-adjusted bias-adjusted kappa was only slightly higher than kappa. Only small differences were found between kappa and bias-adjusted kappa.

CONCLUSION:

The Gillet test, as performed in this study, does not appear to be reliable.

PMID:
10029942
[Indexed for MEDLINE]