U.S. flag

An official website of the United States government

Display Settings:

Items per page

PMC Full-Text Search Results

Items: 8

1.
Figure 2

Figure 2. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Reconstructed geometries of the stents. A, Neuroform2; B, Vision; and C, Wingspan.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
2.
Figure 1

Figure 1. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Geometry of a basilar artery saccular aneurysm and parent artery reconstructed from a patient's computed tomographic angiography images.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
3.
Figure 3

Figure 3. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Geometries of the aneurysm models. U, unstented; N, Neuroform2; V, Vision; W, Wingspan; N2-p, poor deployment double-Neuroform2; N2, double-stent using Neuroform2; NV, double-stent using Neuroform2 and Vision; W2, double-stent using Wingspan; N3, triple-stent using Neuroform2; N2V, triple-stent using two Neuroform2 stents and one Vision stent.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
4.
Figure 5

Figure 5. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Average out-of-plane vorticity in the dome of the aneurysm models. U, unstented; N, Neuroform2; V, Vision; W, Wingspan; N2-p, poor deployment double-Neuroform2; N2, double-stent using Neuroform2; NV, double-stent using Neuroform2 and Vision; W2, double-stent using Wingspan; N3, triple-stent using Neuroform2; N2V, triple-stent using two Neuroform2 stents and one Vision stent.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
5.
Figure 4

Figure 4. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Aneurysmal flow patterns on a midplane of the aneurysm. U, unstented; N, Neuroform2; V, Vision; W, Wingspan; N2-p, poor deployment double-Neuroform2; N2, double-stent using Neuroform2; NV, double-stent using Neuroform2 and Vision; W2, double-stent using Wingspan; N3, triple-stent using Neuroform2; N2V, triple-stent using two Neuroform2 stents and one Vision stent.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
6.
Figure 8

Figure 8. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Aneurysm turnover times (in percent) in the aneurysm models. U, unstented; N, Neuroform2; V, Vision; W, Wingspan; N2-p, poor deployment double-Neuroform2; N2, double-stent using Neuroform2; NV, double-stent using Neuroform2 and Vision; W2, double-stent using Wingspan; N3, triple-stent using Neuroform2; N2V, triple-stent using two Neuroform2 stents and one Vision stent.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
7.
Figure 7

Figure 7. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Examples of low-level wall shear stress (WSS, in Pascals [Pa]) in the aneurysm models. U, unstented; N, Neuroform2; V, Vision; W, Wingspan; N2-p, poor deployment double-Neuroform2; N2, double-stent using Neuroform2; NV, double-stent using Neuroform2 and Vision; W2, double-stent using Wingspan; N3, triple-stent using Neuroform2; N2V, triple-stent using two Neuroform2 stents and one Vision stent.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.
8.
Figure 6

Figure 6. From: QUANTIFICATION OF HEMODYNAMIC CHANGES INDUCED BY VIRTUAL PLACEMENT OF MULTIPLE STENTS ACROSS A WIDE-NECKED BASILAR TRUNK ANEURYSM.

Elevated wall shear stress areas (in percent) in the aneurysm. U, unstented; N, Neuroform2; V, Vision; W, Wingspan; N2-p, poor deployment double-Neuroform2; N2, double-stent using Neuroform2; NV, double-stent using Neuroform2 and Vision; W2, double-stent using Wingspan; N3, triple-stent using Neuroform2; N2V, triple-stent using two Neuroform2 stents and one Vision stent. For example, the colored inset shows WSS distribution of the unstented aneurysm model.

Minsuok Kim, et al. Neurosurgery. ;61(6):1305-1313.

Display Settings:

Items per page

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...
Support Center