Doppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise.
Abstract
Doppler echocardiography was used to measure stroke volume, peak flow velocity, and acceleration of flow in the ascending aorta in 10 healthy young volunteers during unlimited supine bicycle exercise and upright treadmill exercise. High quality studies were obtained in all subjects through the suprasternal notch acoustic window; there was no appreciable degradation in Doppler signal caused by interference by increased respiration or chest wall motion. Stroke volume index increased from 54 ml/m2 at rest to 63.5 ml/m2 at peak supine exercise and from 38 ml/m2 standing at rest to 63.3 ml/m2 during peak upright exercise. Mean peak flow velocity rose from 0.91 m/s at supine rest to 1.36 m/s during maximum supine exercise. In the upright position mean peak flow velocity increased from 0.75 m/s at rest to 1.39 m/s during maximum exercise. Mean peak velocities were lower in the upright position at rest but were not significantly different at peak exercise. Mean acceleration of flow in the ascending aorta increased from 12.02 m/s2 during supine rest to 21.6 m/s2 during supine exercise and from 10.8 m/s2 at rest on the treadmill to 21.9 m/s2 during peak upright exercise. This study shows that echocardiographic measurement of ascending aortic blood flow by the Doppler technique is feasible even during vigorous exercise; that stroke volume and peak flow velocity at rest are lower in the upright position than in the supine position but equalise at peak exercise; and that acceleration of flow in the ascending aorta is the same in both the supine and upright positions and increases equally at peak exercise in both positions.
Full text
Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (1.3M), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References.
Images in this article
Click on the image to see a larger version.
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- RUSHMER RF. Constancy of stroke volume in ventricular responses to exertion. Am J Physiol. 1959 Apr;196(4):745–750. [PubMed]
- Gorlin R, Cohen LS, Elliott WC, Klein MD, Lane FJ. Effect of supine exercise on left ventricular volume and oxygen consumption in man. Circulation. 1965 Sep;32(3):361–371. [PubMed]
- Stenberg J, Astrand PO, Ekblom B, Royce J, Saltin B. Hemodynamic response to work with different muscle groups, sitting and supine. J Appl Physiol. 1967 Jan;22(1):61–70. [PubMed]
- Grimby G, Nilsson NJ, Saltin B. Cardiac output during submaximal and maximal exercise in active middle-aged athletes. J Appl Physiol. 1966 Jul;21(4):1150–1156. [PubMed]
- THEILEN EO, GREGG DE, ROTTA A. Exercise and cardiac work response at high altitude. Circulation. 1955 Sep;12(3):383–390. [PubMed]
- WANG Y, MARSHALL RJ, SHEPHERD JT. The effect of changes in posture and of graded exercise on stroke volume in man. J Clin Invest. 1960 Jul;39:1051–1061. [PMC free article] [PubMed]
- Bevegård S, Freyschuss U, Strandell T. Circulatory adaptation to arm and leg exercise in supine and sitting position. J Appl Physiol. 1966 Jan;21(1):37–46. [PubMed]
- FRICK MH, SOMER T. BASE-LINE EFFECTS ON RESPONSE OF STROKE VOLUME TO LEG EXERCISE IN THE SUPINE POSITION. J Appl Physiol. 1964 Jul;19:639–643. [PubMed]
- REEVES JT, GROVER RF, BLOUNT SG, Jr, FILLEY GF. Cardiac output response to standing and treadmill walking. J Appl Physiol. 1961 Mar;16:283–288. [PubMed]
- Kolettis M, Jenkins BS, Webb-Peploe MM. Assessment of left ventricular function by indices derived from aortic flow velocity. Br Heart J. 1976 Jan;38(1):18–31. [PMC free article] [PubMed]
- Klinke WP, Christie LG, Nichols WW, Ray ME, Curry RC, Pepine CJ, Conti CR. Use of catheter-tip velocity--pressure transducer to evaluate left ventricular function in man: effects of intravenous propranolol. Circulation. 1980 May;61(5):946–954. [PubMed]
- RUSHMER RF. INITIAL VENTRICULAR IMPULSE. A POTENTIAL KEY TO CARDIAC EVALUATION. Circulation. 1964 Feb;29:268–283. [PubMed]
- Ihlen H, Amlie JP, Dale J, Forfang K, Nitter-Hauge S, Otterstad JE, Simonsen S, Myhre E. Determination of cardiac output by Doppler echocardiography. Br Heart J. 1984 Jan;51(1):54–60. [PMC free article] [PubMed]
- Crawford MH, White DH, Amon KW. Echocardiographic evaluation of left ventricular size and performance during handgrip and supine and upright bicycle exercise. Circulation. 1979 Jun;59(6):1188–1196. [PubMed]
- Huntsman LL, Stewart DK, Barnes SR, Franklin SB, Colocousis JS, Hessel EA. Noninvasive Doppler determination of cardiac output in man. Clinical validation. Circulation. 1983 Mar;67(3):593–602. [PubMed]
- Magnin PA, Stewart JA, Myers S, von Ramm O, Kisslo JA. Combined doppler and phased-array echocardiographic estimation of cardiac output. Circulation. 1981 Feb;63(2):388–392. [PubMed]
- Nishimura RA, Callahan MJ, Schaff HV, Ilstrup DM, Miller FA, Tajik AJ. Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature. Mayo Clin Proc. 1984 Jul;59(7):484–489. [PubMed]
- Loeppky JA, Greene ER, Hoekenga DE, Caprihan A, Luft UC. Beat-by-beat stroke volume assessment by pulsed Doppler in upright and supine exercise. J Appl Physiol Respir Environ Exerc Physiol. 1981 Jun;50(6):1173–1182. [PubMed]
- WILSON MF. Left ventricular diameter, posture, and exercise. Circ Res. 1962 Jul;11:90–95. [PubMed]
- Parker JO, Case RB. Normal left ventricular function. Circulation. 1979 Jul;60(1):4–12. [PubMed]
- Poliner LR, Dehmer GJ, Lewis SE, Parkey RW, Blomqvist CG, Willerson JT. Left ventricular performance in normal subjects: a comparison of the responses to exercise in the upright and supine positions. Circulation. 1980 Sep;62(3):528–534. [PubMed]
- Horwitz LD, Atkins JM, Leshin SJ. Role of the Frank-Starling mechanism in exercise. Circ Res. 1972 Dec;31(6):868–875. [PubMed]
- Vatner SF, Franklin D, Higgins CB, Patrick T, Braunwald E. Left ventricular response to severe exertion in untethered dogs. J Clin Invest. 1972 Dec;51(12):3052–3060. [PMC free article] [PubMed]
- GREENFIELD JC, Jr, PATEL DJ. Relation between pressure and diameter in the ascending aorta of man. Circ Res. 1962 May;10:778–781. [PubMed]
- Colocousis JS, Huntsman LL, Curreri PW. Estimation of stroke volume changes by ultrasonic doppler. Circulation. 1977 Dec;56(6):914–917. [PubMed]
Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group