TABLE 2-6Seamless Dip-Coated Shell Elastomer, Platinum Cure

No.Chemical NameFunctionMDF-0077, O and I, STD (%)Q7-2423, II and MSI, HP (%)Q7-2551, FluoroSil Barrier (%)
TCE1,1,1-TrichloroethaneSolvent84.8188.8648.73
AcetoneAcetoneSolvent48.73
SGM-IIVi-terminated Me2Vi-co-MeVi siloxaneReactive copolymer9.36
SGM-35Vi-terminated Me2Vi-co-MeVi siloxaneReactive copolymer0.78
SGM-24Vi-terminated Me2Vi-co-MeVi siloxaneReactive copolymer0.035
SGM-26Vi-terminated PDMSReactive copolymer7.03
SGM-900MeVi-co-F3PrMe siloxaneReactive copolymer1.9
MS-75DSilica aerogelFiller0.42
R-972Me3Si-treated aerogelFiller5.63.16
PA FluidHO-terminated PDMSProcess aid0.15
ZnStZinc stearateRelease agent0.0370.02
XR-63570Me2-co-MeH siloxaneCross-linker0.090.11
1107MeH siloxaneCross-linker0.031
MeBuMethylbutynolCure retarder0.04
ETCH1-Ethynyl-1-cyclohexanolCure retarder0.010.005
MDF-0069Cyclo(MeViSiO)4:Pt complexCatalyst0.09
Platinum II(Me2ViSi)2 in O:Pt complexCatalyst0.0140.008

From: 2, Silicone Chemistry

Cover of Safety of Silicone Breast Implants
Safety of Silicone Breast Implants.
Institute of Medicine (US) Committee on the Safety of Silicone Breast Implants; Bondurant S, Ernster V, Herdman R, editors.
Washington (DC): National Academies Press (US); 1999.
Copyright © 2000, National Academy of Sciences.

NCBI Bookshelf. A service of the National Library of Medicine, National Institutes of Health.