Table 80Cost of CGM strategy

InterventionItemUnit costUnits per yearAnnual cost
Dexcom G4Receiver£17501/5£374a
Sensors£250/452£3,250
Transmitters£2752£550
Calibration£0.292*365b£212
Total £4,392
Abbott FreestyleReceiver£9501/5£203a
Sensors£288/660£2,880
TransmittersNac00
Calibration£0.291*365d£106
Total £3,189
Medtronic RT GuardianReceiver£1,059e1/5£227a
Sensors£420/1060£2,520
Transmitters£490f1f£490
Calibration£0.292*365b£212
Total £2,965
Total average cost (first year) £3,511
Total average cost (second year and after) £3,674
a

Annual cost estimated assuming a five year life span and a discount (dis) of 3.5% using the formula: purchase cost/(1-1/(1+dis)^(life span -1))/dis)

b

Assuming SMBG for calibration is performed twice a day

c

Rechargeable

d

On average calibration is performed once per day

e

Total initial cost of £1,599 included also the cost of sensors, which has been subtracted by the initial cost.

f

Except for the first year

From: 8, Blood glucose control

Cover of Type 1 Diabetes in Adults: Diagnosis and Management
Type 1 Diabetes in Adults: Diagnosis and Management.
NICE Guideline, No. 17.
National Clinical Guideline Centre (UK).
Copyright © 2015 National Clinical Guideline Centre.