    J Pediatr. 2005 Sep;147(3):396-8.

    Continuous glucose monitoring in adolescents with cystic fibrosis.

    Source

    Division of Endocrinology, Hospital for Sick Children, University of Toronto. Toronto, Ontario, Canada. c.jefferies@auckland.ac.nz

    Abstract

    The presence of cystic fibrosis (CF)-related diabetes was evaluated in 19 adolescents with CF by continuous glucose monitoring system (CGMS) and oral glucose tolerance testing. CGMS confirmed diabetic glucose excursions in 7/19 subjects deemed diabetic on oral glucose tolerance testing. CGMS is a useful tool for detecting hyperglycemia in CF.