Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

    Results: 1 to 20 of 161

    1.

    Microfungal contamination of damp buildings--examples of risk constructions and risk materials.

    Gravesen S, Nielsen PA, Iversen R, Nielsen KF.

    Environ Health Perspect. 1999 Jun;107 Suppl 3:505-8.PMID: 10347000 [PubMed - indexed for MEDLINE]Related articlesFree article

    2.

    Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins in the indoor environment.

    Brasel TL, Martin JM, Carriker CG, Wilson SC, Straus DC.

    Appl Environ Microbiol. 2005 Nov;71(11):7376-88.PMID: 16269780 [PubMed - indexed for MEDLINE]Related articlesFree article

    3.

    Mass spectrometry-based strategy for direct detection and quantification of some mycotoxins produced by Stachybotrys and Aspergillus spp. in indoor environments.

    Bloom E, Bal K, Nyman E, Must A, Larsson L.

    Appl Environ Microbiol. 2007 Jul;73(13):4211-7. Epub 2007 May 4.PMID: 17483261 [PubMed - indexed for MEDLINE]Related articlesFree article

    4.

    Mycotoxins in crude building materials from water-damaged buildings.

    Tuomi T, Reijula K, Johnsson T, Hemminki K, Hintikka EL, Lindroos O, Kalso S, Koukila-Kähkölä P, Mussalo-Rauhamaa H, Haahtela T.

    Appl Environ Microbiol. 2000 May;66(5):1899-904.PMID: 10788357 [PubMed - indexed for MEDLINE]Related articlesFree article

    5.

    Mycotoxin production by indoor molds.

    Fog Nielsen K.

    Fungal Genet Biol. 2003 Jul;39(2):103-17. Review.PMID: 12781669 [PubMed - indexed for MEDLINE]Related articles

    6.

    Adverse human health effects associated with molds in the indoor environment.

    Hardin BD, Kelman BJ, Saxon A.

    J Occup Environ Med. 2003 May;45(5):470-8. Review.PMID: 12762072 [PubMed - indexed for MEDLINE]Related articles

    7.

    Mycotoxins as harmful indoor air contaminants.

    Jarvis BB, Miller JD.

    Appl Microbiol Biotechnol. 2005 Jan;66(4):367-72. Epub 2004 Nov 23. Review.PMID: 15565335 [PubMed - indexed for MEDLINE]Related articles

    8.

    Molds and mycotoxins in indoor environments--a survey in water-damaged buildings.

    Bloom E, Nyman E, Must A, Pehrson C, Larsson L.

    J Occup Environ Hyg. 2009 Nov;6(11):671-8.PMID: 19757292 [PubMed - indexed for MEDLINE]Related articles

    9.

    Building-associated pulmonary disease from exposure to Stachybotrys chartarum and Aspergillus versicolor.

    Hodgson MJ, Morey P, Leung WY, Morrow L, Miller D, Jarvis BB, Robbins H, Halsey JF, Storey E.

    J Occup Environ Med. 1998 Mar;40(3):241-9.PMID: 9531095 [PubMed - indexed for MEDLINE]Related articles

    10.

    Production of mycotoxins on artificially and naturally infested building materials.

    Nielsen KF, Gravesen S, Nielsen PA, Andersen B, Thrane U, Frisvad JC.

    Mycopathologia. 1999;145(1):43-56.PMID: 10560628 [PubMed - indexed for MEDLINE]Related articles

    11.

    Detection of satratoxin g and h in indoor air from a water-damaged building.

    Gottschalk C, Bauer J, Meyer K.

    Mycopathologia. 2008 Aug;166(2):103-7. Epub 2008 Apr 29.PMID: 18443920 [PubMed - indexed for MEDLINE]Related articles

    12.

    Stachybotrys chartarum (chartarum = atra = alternans) and other problems caused by allergenic fungi.

    Chapman JA.

    Allergy Asthma Proc. 2003 Jan-Feb;24(1):1-7. Review.PMID: 12635571 [PubMed - indexed for MEDLINE]Related articles

    13.

    Mold infestation of wet spray-applied cellulose insulation.

    Godish TJ, Godish DR.

    J Air Waste Manag Assoc. 2006 Jan;56(1):90-5.PMID: 16499151 [PubMed - indexed for MEDLINE]Related articles

    14.

    Effect of building frame and moisture damage on microbiological indoor air quality in school buildings.

    Meklin T, Hyvärinen A, Toivola M, Reponen T, Koponen V, Husman T, Taskinen T, Korppi M, Nevalainen A.

    AIHA J (Fairfax, Va). 2003 Jan-Feb;64(1):108-16.PMID: 12570403 [PubMed - indexed for MEDLINE]Related articles

    15.

    Bacterial strains from moldy buildings are highly potent inducers of inflammatory and cytotoxic effects.

    Hirvonen MR, Huttunen K, Roponen M.

    Indoor Air. 2005;15 Suppl 9:65-70.PMID: 15910531 [PubMed - indexed for MEDLINE]Related articles

    16.

    Effects on perceived air quality and symptoms of exposure to microbially produced metabolites and compounds emitted from damp building materials.

    Claeson AS, Nordin S, Sunesson AL.

    Indoor Air. 2009 Apr;19(2):102-12. Epub 2008 Oct 15.PMID: 19077173 [PubMed - indexed for MEDLINE]Related articles

    17.

    An environmental assessment of mold concentrations and potential mycotoxin exposures in the greater Southeast Texas area.

    Khan NN, Wilson BL.

    J Environ Sci Health A Tox Hazard Subst Environ Eng. 2003;38(12):2759-72.PMID: 14672314 [PubMed - indexed for MEDLINE]Related articles

    18.

    Evaluation of fungal growth on cellulose-containing and inorganic ceiling tile.

    Karunasena E, Markham N, Brasel T, Cooley JD, Straus DC.

    Mycopathologia. 2001;150(2):91-5.PMID: 11407495 [PubMed - indexed for MEDLINE]Related articles

    19.

    Indoor air microbes and respiratory symptoms of children in moisture damaged and reference schools.

    Meklin T, Husman T, Vepsäläinen A, Vahteristo M, Koivisto J, Halla-Aho J, Hyvärinen A, Moschandreas D, Nevalainen A.

    Indoor Air. 2002 Sep;12(3):175-83.PMID: 12244747 [PubMed - indexed for MEDLINE]Related articles

    20.

    Testing antimicrobial cleaner efficacy on gypsum wallboard contaminated with Stachybotrys chartarum.

    Menetrez MY, Foarde KK, Webber TD, Dean TR, Betancourt DA.

    Environ Sci Pollut Res Int. 2007 Nov;14(7):523-8.PMID: 18062486 [PubMed - indexed for MEDLINE]Related articles

    Supplemental Content

    Find related data