Compressed Sensing Image Reconstruction of Ultrasound Image for Treatment of Early Traumatic Myositis Ossificans of Elbow Joint by Electroacupuncture

J Healthc Eng. 2021 Dec 7:2021:4066415. doi: 10.1155/2021/4066415. eCollection 2021.

Abstract

This article conducts a retrospective analysis of 500 patients with posttraumatic elbow dysfunction admitted to our department from March 2019 to September 2020. The average time from injury to operation is 11 months (2-20 months). We adopt a personalized treatment method to completely remove the hyperplastic adhesion tissue and heterotopic ossification around the joint, remove part of the joint capsule and ligament, and release it to achieve maximum function. After the operation, an external fixator was used to stabilize the loosened elbow joint, and the patient was guided to perform rehabilitation exercises with the aid of a hinged external fixator, and celecoxib was used to prevent heterotopic ossification. Mayo functional scoring system was used to evaluate the curative effect before and after surgery. The rapid realization of ultrasound imaging under the framework of compressed sensing is studied. Under the premise of ensuring the quality of ultrasound imaging reconstruction, the theory of ultrasound imaging is improved, and a plane wave acoustic scattering ultrasound echo model is established. On this basis, the theory of compressed sensing is introduced, the mathematical model of compressed sensing reconstruction is established, and the fast iterative shrinkage thresholding algorithm (FISTA) of compressed sensing reconstruction is improved to reduce the computational complexity and the number of iterations. This article uses FISTA directly to reconstruct medical ultrasound images, and the reconstruction results are not ideal. Therefore, a simulation model of FISTA training and testing was established using the standard image library. By adding different intensities of noise to all images in the image library, the influence of noise intensity on the quality of FISTA reconstructed images is analyzed, and it is found that the FISTA model has requirements for the quality of the images to be reconstructed and the training set images. In this paper, Rob's blind deconvolution restoration algorithm is used to preprocess the original ultrasound image. The clarity of the texture details of the restored ultrasound image is significantly improved, and the image quality is improved, which meets the above requirements. This paper finally formed a reconstruction model suitable for ultrasound images. The reconstruction strategy verified by the ultrasound images provided by the Institute of Ultrasound Imaging of a medical university has achieved a significant improvement in the quality of ultrasound images.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Elbow Joint* / diagnostic imaging
  • Electroacupuncture*
  • Humans
  • Image Processing, Computer-Assisted
  • Myositis Ossificans*
  • Retrospective Studies
  • Ultrasonography