A novel automated diagnostic system for classification of myocardial infarction ECG signals using an optimal biorthogonal filter bank

Comput Biol Med. 2018 Nov 1:102:341-356. doi: 10.1016/j.compbiomed.2018.07.005. Epub 2018 Jul 23.

Abstract

Myocardial infarction (MI), also referred to as heart attack, occurs when there is an interruption of blood flow to parts of the heart, due to the acute rupture of atherosclerotic plaque, which leads to damage of heart muscle. The heart muscle damage produces changes in the recorded surface electrocardiogram (ECG). The identification of MI by visual inspection of the ECG requires expert interpretation, and is difficult as the ECG signal changes associated with MI can be short in duration and low in magnitude. Hence, errors in diagnosis can lead to delay the initiation of appropriate medical treatment. To lessen the burden on doctors, an automated ECG based system can be installed in hospitals to help identify MI changes on ECG. In the proposed study, we develop a single-channel single lead ECG based MI diagnostic system validated using noisy and clean datasets. The raw ECG signals are taken from the Physikalisch-Technische Bundesanstalt database. We design a novel two-band optimal biorthogonal filter bank (FB) for analysis of the ECG signals. We present a method to design a novel class of two-band optimal biorthogonal FB in which not only the product filter but the analysis lowpass filter is also a halfband filter. The filter design problem has been composed as a constrained convex optimization problem in which the objective function is a convex combination of multiple quadratic functions and the regularity and perfect reconstruction conditions are imposed in the form linear equalities. ECG signals are decomposed into six subbands (SBs) using the newly designed wavelet FB. Following to this, discriminating features namely, fuzzy entropy (FE), signal-fractal-dimensions (SFD), and renyi entropy (RE) are computed from all the six SBs. The features are fed to the k-nearest neighbor (KNN). The proposed system yields an accuracy of 99.62% for the noisy dataset and an accuracy of 99.74% for the clean dataset, using 10-fold cross validation (CV) technique. Our MI identification system is robust and highly accurate. It can thus be installed in clinics for detecting MI.

Keywords: Electrocardiogram; Entropy; Fractal dimension; KNN; Optimal biorthogonal filter bank; Stopband energy.

MeSH terms

  • Algorithms
  • Area Under Curve
  • Cluster Analysis
  • Diagnosis, Computer-Assisted / methods
  • Electrocardiography*
  • Female
  • Fractals
  • Fuzzy Logic
  • Heart
  • Humans
  • Male
  • Myocardial Infarction / diagnosis*
  • Pattern Recognition, Automated / methods*
  • Reproducibility of Results
  • Signal Processing, Computer-Assisted
  • Wavelet Analysis