Relating Fresh Concrete Viscosity Measurements from Different Rheometers

J Res Natl Inst Stand Technol. 2003 Jun 1;108(3):229-34. doi: 10.6028/jres.108.021. Print 2003 May-Jun.

Abstract

Concrete rheological properties need to be properly measured and predicted in order to characterize the workability of fresh concrete, including special concretes such as self-consolidating concrete (SCC). It was shown by a round-robin test held in 2000 [1,2] that different rheometer designs gave different values of viscosity for the same concrete. While empirical correlation between different rheometers was possible, for a procedure that is supposed to "scientifically" improve on the empirical slump tests, this situation is unsatisfactory. To remedy this situation, a new interpretation of the data was developed. In this paper, it is shown that all instruments tested could be directly and quantitatively compared in terms of relative plastic viscosity instead of the plastic viscosity alone. This should eventually allow the measurements from various rheometer designs to be directly calibrated against known standards of plastic viscosity, putting concrete rheometry and concrete workability on a sounder materials science basis.

Keywords: concrete rheometers; dissipative particle dynamics modeling; plastic viscosity; rheology.