Masseter muscle thickness, chewing efficiency and bite force in edentulous patients with fixed and removable implant-supported prostheses: a cross-sectional multicenter study

Clin Oral Implants Res. 2012 Feb;23(2):144-150. doi: 10.1111/j.1600-0501.2011.02213.x. Epub 2011 Jun 2.

Abstract

Objectives: Edentulous patients may be restored with conventional dentures (C/C), implant-supported overdentures (IOD) or implant-supported fixed dental prostheses (IFDP). Null-hypotheses: chewing efficiency, maximum voluntary bite force (MBF) and masseter muscle thickness (MMT) are lower in patients with C/IOD compared with the patients with bimaxillary IFDPs. Both groups perform better than C/C and are inferior to fully dentate controls.

Material and methods: Ethical approval was obtained. For this multicenter cross-sectional study, 80 patients were recruited. Four groups of different dental states comprised of either implant-supported prostheses (C/IOD and IFDP/IFDP) or served as control-groups (C/C and fully dentate D/D). Chewing efficiency was assessed with a two-colour mixing ability test. MBF was measured bilaterally with a force gauge. Two dimensional ultrasonography was used to measure MMT bilaterally.

Results: Chewing efficiency in C/IOD and IFDP/IFDP (difference NS) was better than in C/C, but not as good as in D/D. MBF in C/IOD was lower than in IFDP/IFDP. Chewing efficiency and MBF were significantly lower in IFDP/IFDP, who had experienced chipping or fracture of the prosthetic superstructure. Median MMT of patients with implant-supported prostheses was between those with C/C and fully dentate participants. There was no significant difference in MMT between C/IOD and IFDP/IFDP.

Conclusion: Supporting complete prostheses with oral implants seems to have positive effects on the thickness of the masseter muscle, maximum bite force as well as chewing efficiency. The type of implant-supported prostheses may have an influence on the magnitude of the effect.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Bite Force
  • Chi-Square Distribution
  • Cross-Sectional Studies
  • Dental Prosthesis, Implant-Supported*
  • Denture, Overlay
  • Denture, Partial, Fixed
  • Female
  • Humans
  • Male
  • Masseter Muscle / diagnostic imaging
  • Masseter Muscle / physiology*
  • Mastication / physiology*
  • Middle Aged
  • Mouth, Edentulous / rehabilitation*
  • Statistics, Nonparametric
  • Ultrasonography