An in vitro study of cryopreserved and fresh human arteries: a comparison with ePTFE prostheses and human arteries studied non-invasively in vivo

Cryobiology. 2006 Feb;52(1):17-26. doi: 10.1016/j.cryobiol.2005.09.001. Epub 2005 Nov 7.

Abstract

The surgical options in arterial reconstruction are: the use of autologous arteries; autologous veins; or expanded polytetrafluoroethylene (ePTFE) grafts. However, the development of intimal hyperplasia when using veins or ePTFE grafts has been associated with graft failure. Since autologous arteries are not always available, the use of cryopreserved arteries has to be considered. The aims of this study were: (a) to compare the viscoelastic properties of stored cryopreserved arteries and fresh arteries by in vitro analysis; and (b) to compare the viscoelastic properties of arteries measured non-invasively in normotensive patients, with fresh arteries, cryopreserved arteries, and ePTFE segments. The viscoelastic studies were performed in normotensive patients using stress-strain analysis with non-invasive measurement of pressure and diameter in the common carotid artery, and in vitro measurements of pressure and diameter in arteries and prostheses. The in vitro studies showed that the elastic modulus (E), viscous modulus (eta), Stiffness Index (SI), Peterson modulus (Ep), and the pulse wave velocity (PWV) values for human cryopreserved carotid arteries were similar to the values obtained non-invasively in normotensive subjects (P>0.05) and to human fresh vessels (P>0.05). In vitro, the SI, Ep, PWV, and E values of ePTFE were significantly higher than the observed values in subjects and with fresh and cryopreserved arteries (P<0.05); on the other hand the ePTFE eta values were the lowest (P<0.05). We concluded that cryopreserved arteries have similar viscoelastic properties to those obtained in vivo in the arteries of normotensive subjects and in vitro in fresh arteries. Consequently, we conclude that the cryopreservation procedure does not modify the mechanical properties of the arterial wall.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Arteries / pathology*
  • Blood Vessel Prosthesis*
  • Cryopreservation / methods*
  • Cryoprotective Agents / pharmacology
  • Elasticity
  • Female
  • Humans
  • In Vitro Techniques
  • Male
  • Middle Aged
  • Models, Biological
  • Polytetrafluoroethylene / classification
  • Polytetrafluoroethylene / pharmacology*
  • Viscosity

Substances

  • Cryoprotective Agents
  • Polytetrafluoroethylene